@ARTICLE{
author={Hadziefendic Nedzad,Kostic Nemanja,Trifunovic Jovan,Kostic Miomir B},
year={2019},
title={Detection of Poor Contacts in Low-Voltage Electrical Installations},
journal={IEEE TRANSACTIONS ON COMPONENTS PACKAGING AND MANUFACTURING TECHNOLOGY},
volume={9},
number={1},
pages={129-137},
document_type={Article},
} 

@ARTICLE{
author={Hadziefendic Nedzad,Trifunovic Jovan,Kostic Miomir B},
year={2018},
title={Effects of a Reduced Torque on Heating of Electrical Contacts in Plugs and Receptacles},
journal={IEEE TRANSACTIONS ON COMPONENTS PACKAGING AND MANUFACTURING TECHNOLOGY},
volume={8},
number={11},
pages={1905-1913},
document_type={Article},
} 

@ARTICLE{
author={Trifunovic Jovan},
year={2018},
title={A Mathematical Method for Determining Optimal Quantity of Backfill Materials Used for Grounding Resistance Reduction},
journal={MATHEMATICAL PROBLEMS IN ENGINEERING},
volume={},
number={},
pages={-},
document_type={Article},
} 

@ARTICLE{
author={Trifunovic Jovan,Kostic Miomir B},
year={2016},
title={Quick calculation of the grounding resistance of a typical 110 kV transmission line tower grounding system},
journal={ELECTRIC POWER SYSTEMS RESEARCH},
volume={131},
number={},
pages={178-186},
document_type={Article},
} 

@ARTICLE{
author={Trifunovic Jovan,Kostic Miomir B},
year={2015},
title={An Algorithm for Estimating the Grounding Resistance of Complex Grounding Systems Including Contact Resistance},
journal={IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS},
volume={51},
number={6},
pages={5167-5174},
document_type={Article},
} 

@ARTICLE{
author={Trifunovic Jovan,Kostic Miomir B},
year={2014},
title={Analysis of influence of imperfect contact between grounding electrodes and surrounding soil on electrical properties of grounding loops},
journal={ELECTRICAL ENGINEERING},
volume={96},
number={3},
pages={255-265},
document_type={Article},
} 

@ARTICLE{
author={Trifunovic Jovan},
year={2012},
title={The Algorithm for Determination of Necessary Characteristics of Backfill Materials Used for Grounding Resistances of Grounding Loops Reduction},
journal={JOURNAL OF ELECTRICAL ENGINEERING-ELEKTROTECHNICKY CASOPIS},
volume={63},
number={6},
pages={373-379},
document_type={Article},
} 

@ARTICLE{
author={Trifunovic Jovan,Mikulovic Jovan C,Djurisic Zeljko R,Kostic Miomir B},
year={2011},
title={Reductions in electricity losses in the distribution power system in case of the mass use of compact fluorescent lamps},
journal={ELECTRIC POWER SYSTEMS RESEARCH},
volume={81},
number={2},
pages={465-477},
document_type={Article},
} 

@ARTICLE{
author={Trifunovic Jovan,Mikulovic Jovan C,Djurisic Zeljko R,Djuric Milenko B,Kostic Miomir B},
year={2009},
title={Reductions in electricity consumption and power demand in case of the mass use of compact fluorescent lamps},
journal={ENERGY},
volume={34},
number={9},
pages={1355-1363},
document_type={Article},
} 

@ARTICLE{
author={Djurisic Zeljko R,Kunosic Amir,Trifunovic Jovan},
year={2006},
title={Influence of process parameters in pulse plasma nitriding of plain carbon steel},
journal={SURFACE ENGINEERING},
volume={22},
number={2},
pages={147-152},
document_type={Article},
} 

